It is a good idea to always close any explicitedly opened refnums! Disable that one and enable ANOTHER. This error can occur if VI Server is used with a VI that has a password protected diagram. All rights reserved. | Jump to content LabVIEW General Existing user? this content

Great news, but i still don't understand : 1)You say you remember there was a bug fixe ... Please tell us why. From the Run Method Help: Auto Dispose Ref: If TRUE, the target VI detaches the reference from the main VI. Edwards Deming cont_mult_vis_rem_pan.zip ‏157 KB 0 Kudos Message 5 of 7 (634 Views) Reply 0 Kudos Re: Error 1000 vi is not in a state compatible [Edited] CoastalMaineBi… Trusted Enthusiast ‎02-27-2013 you can try this out

Error 1044: The VI is locked When running as a standalone application, a Property Node in the VI might return error 1044, which causes the called VI not to be opened Make sure you are using \ instead of /, make sure you spelled the directory names correctly, and so on. All rights reserved. | Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 13 ratings: 3.69 out of 5   Why Do Both "A" & "B" work without problems when the VIs are running under the LabVIEW development system. "A" can also start "B" without problems running under the development system.

When I open and run the vis by reference method in the top-level vi everything works fine. Thanks in advance. You must close this reference before you can edit the VI. Sign In Now Sign in to follow this Followers 0 Go To Topic Listing LabVIEW General All Activity Home Software & Hardware Discussions LabVIEW General Calling a VI using VI Server

A VI cannot be edited while the VI is actually running. Active Participant ‎02-27-2013 07:48 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator I have used subpanels before and Using the type specifier allows you to call the VI using a Call By Reference Node. https://forums.ni.com/t5/LabVIEW/Error-1000/td-p/3075066 Double-check the path you entered.

Now accompanied by LabVIEW 2011, this classic second edition, focusing on LabVIEW 8.0, delves deeply into...https://books.google.com/books/about/LabView.html?id=L-fKBQAAQBAJ&utm_source=gb-gplus-shareLabViewMy libraryHelpAdvanced Book SearchGet print bookNo eBook availableCRC PressAmazon.comBarnes&Noble.comBooks-A-MillionIndieBoundAll sellers»Get Textbooks on Google PlayRent and save All are set up the same way in properties. Ahhhhh - of course it does! Share this post Link to post Share on other sites crelf 274 I'm a LAVA, not a fighter.

Thanks for the explination - I agree: I've had the same issue in the past, but the problem that I'm currently having happens in the development environment - I haven't even http://digital.ni.com/public.nsf/allkb/E1B8CA0B546A803486256A33005AF221 If the string was not truncated then [requiredSize] wil be less than or equal to [stringLength].

info: the information that the driver should return. United States MY ACCOUNT   INNOVATIONS SHOP SUPPORT COMMUNITY Home Community Home : Discussion Forums : Most Active Software Boards : LabVIEW : Error 1000 vi is not in a state Members 92 3,839 posts Location:Lafayette, CA Version:LabVIEW 2014 Posted March 4, 2006 I'm not useing the CBRN because I need the plugin to run in parallel to the rest of the

PaulG."Without data you're just another person with an opinion." - W. news It's easy! I corrected my current problem using a Stop shared variable. Thanks a lot for your answer, as you said i replace the Method Run vi with the Start Asynchronous Call and now i don't have any error when i try to

As i said, there are differents weird things: 1) When i check the state of the vi it remains in Running state during 5s.... 2) After this i try to abort Sign In Sign Up Browse Back Browse Forums Downloads Gallery Staff Online Users Activity Back Activity All Activity My Activity Streams Unread Content Content I Started Search My AccountSearchMapsYouTubePlayNewsGmailDriveCalendarGoogle+TranslatePhotosMoreShoppingWalletFinanceDocsBooksBloggerContactsHangoutsEven more from My original problem/complaint:I have 4 subvis/subpanels. have a peek at these guys Primary Software: LabVIEW Development Systems>>LabVIEW Base Development System Primary Software Version: 5.0 Primary Software Fixed Version: N/A Secondary Software: N/A Problem: I am getting the following error when trying to change

When a VI is reserved for running (or is running), you cannot edit it. See the examples in 2014 0 Kudos Message 5 of 8 (510 Views) Reply 0 Kudos Re: Error 1000 kabooom Member ‎01-15-2015 01:25 AM Options Mark as New Bookmark Subscribe Subscribe Active Participant ‎02-21-2013 08:07 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator There is quite a lot of

does it mean that 0D error is PICO_INVALID_PARAMETER ?How to fix this problem ?

Share this post Link to post Share on other sites jpdrolet 2 Extremely Active Members 2 367 posts Version:LabVIEW 2009 Since:2009 Posted March 7, 2006 I think that you wouldn't As the series title implies, the scripts (of which there are more than 200) described in the text and supplied in code form (available via the internet at www.morganclaypool.com/page/isen) will run You don't just don't need it, you can't wire it to use the Run method. I think i will contact NI for further informations ....

If you are enforcing a strict con-pane adherance of plug-ins, then this might be the best approach. In this case we will have BIG problem... In that example, the subVIs stop because there is NOTHING ELSE RUNNING (their parents died, so to speak). http://ascadys.net/labview-error/labview-error-10.html Take a look atThis JING: (you need audio ON) --- I changed VI1 to beep every 2 seconds, so you could tell it's running. --- I changed MAIN vi

Close.png ‏53 KB 0 Kudos Message 1 of 8 (547 Views) Reply 0 Kudos Re: Error 1000 [Edited] Sam_Sharp Trusted Enthusiast ‎01-14-2015 07:09 AM - edited ‎01-14-2015 07:11 AM Options Mark I encountered problem when I do not know What that handler do in picoLog example files.Why handle have to be 0 ? I know that I I don't need to use a specifier to just run a VI dynamically, but I'm using it this way so the error cluster allows me to determine Error 1043: Feature not supported in this application This error can occur when you use an Invoke Node and the Save Instrument method (or another similar function) in an application.