Home > Labview Error > Labview Error Code 30

Labview Error Code 30

Recompiling the VI may fix this issue. 4800 Selected Device is Invalid The currently selected device index is invalid. To correct this error, save to a folder instead of an LLB. 1497 Cannot unlock a library for edit when instances in running VIs exist. 1498 Library has errors. This normally is a user data file. 99 Incorrect file version. This error occurs when you try to use the Default Frame property with a Diagram Disable structure. this content

For example, the default interface name for NI boards is GPIB0, but you may misspell it as GPIBO (with an "oh" instead of a zero). To run a VI using a static VI reference, use an Invoke Node to call the Run VI method. A palette item is invalid. Navigate to \National Instruments\Shared\MDF\Manifests9. https://forums.ni.com/t5/LabVIEW/Why-do-i-get-Error-Code-30-after-recompile-of-working-code/td-p/3178798

Error Code 00: This code is not an error, it indicates that the updating of the EEPROM firmware was successful. To correct this error, ensure the target VI is idle or reentrant. Copy this new Alphanumeric ID. On Windows, navigate to the file, right-click the file, select Properties, and set the Read-only option in the dialog box.

Add Comments 1 2 3 4 5 My Profile|Privacy|Legal|Contact NI© National Instruments Corporation. Code Description −2147467259 Unspecified error. −1967345152 Invalid refnum. For example, VI Server:Generic:GObject 1312 Structure frame index is out of range. Consider building caches for each set of paths that share a common directory. 1580 Cannot find the compiled code in the compiled object cache.

You also can use the Front Panel:Open method to open the front panel programmatically. 1002 The VI cannot run because it has a front panel control in an error state. 1003 Solution: This error is caused by stale dependenciesthat occasionally remain after upgrading NI products. Install SignalExpress or visit www.ni.com/signalexpress to download an evaluation version. −40601 The deterministic communication engine failed to initialize hardware. −4850 Device driver not present or not supported. http://forums.ni.com/t5/LabVIEW/I-get-a-message-like-quot-labview-load-error-code-30-could-not/td-p/32950 To correct this error, save to a folder instead of an LLB. 1497 Cannot unlock a library for edit when instances in running VIs exist. 1498 Library has errors.

The ibcmd function causes the ATN line to be asserted, which tells instruments to expect command messages, instead of data messages. Poor|Excellent Yes No Document Quality? If this error is returned from the Open VI Reference function on a remote connection, use the VI Server page of the Options dialog box to ensure that the VI is To correct this error, install the latest version of DirectX from http://www.microsoft.com/downloads. 4810 Cannot recognize sound format.

If create if not found? A bad format specifier was found in the Format String input to a Format Into String or Scan From String function. 83 Too few format specifiers. If it is reentrant, use the Open VI Reference function with the options input set to 0x08 to prepare the VI for reentrant run or use the Open VI Reference function You can use the Conditions property and the Get Frame Index method only with the Conditional Disable structure. 1378 Cannot set the Active Frame property on a Conditional Disable structure.

Try freeing up disk space or saving to a different disk or drive. news You also can receive this error if the Scan From File or Scan From String functions reach the end of the file. For example: [ ( 3 long flashes - 1 ) x 10 ] + [ 4 short flashes - 1 ] = Error Code 23 Before attempting to resolve errors, verify The input for class name is not correct or is in the wrong format.

Change the display mode to 0 (normal) and/or disable word wrapping to use this property. 1363 The specified name or GUID is invalid. 1364 The provider plug-in is not installed or A buffer underflow has occurred because the application is not writing data quickly enough. −4803 The sound driver or card does not support the specified operation. The Connectivity VIs are available for free download from ni.com. http://ascadys.net/labview-error/labview-error-code-3.html Open the _edit.log file in that directory.4.

Wait until the VI is not being modified to get the image of a panel or diagram. 1001 The VI front panel is not open. This error might occur if the create if not found input of the Obtain Semaphore Reference VI is FALSE and LabVIEW cannot find a semaphore with the name you specify. 1535 Attachments: Report Date: 09/28/1998 Last Updated: 08/23/2016 Document ID: 1DREQIQA Your Feedback!

The lock prevents giving the untitled item a name so it cannot be saved. 1571 You cannot open a packed library saved in a version earlier than the current version of

Select File¬ĽOpen to open the VI and then verify that you are able to run it. 1004 The VI is not in memory. 1005 VI execution has been disabled in the When LabVIEW tries to move the splitter bar to the specified position, at least one pane shrinks smaller than its set minimum size. To correct this error, install the latest version of DirectX from http://www.microsoft.com/downloads. 4810 Cannot recognize sound format. The control reference of the control does not belong to the VI that owns the Property or Invoke Node. 1311 The input for class name is not correct or is in

The long flashes are followed by short flashes. You cannot use the prefix LV_ on a data name. 1362 Cannot use this property with this string display mode or if word wrapping is enabled. If you receive this error while trying to run File I/O VIs, refer to the KnowledgeBase at ni.com for more information. 2 Memory is full. check my blog Try updating the firmware again.

Set the Type of Dialog node of the error handler VI to 0 (zero).