Home > Labview Error > Labview Error Code 91

Labview Error Code 91

Go to Solution motivation behind variant and error code 91. [Edited] nizamani Member ‎11-11-2012 12:20 PM - edited ‎11-11-2012 12:20 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed The specified sound file could not be found. 4806 DirectX 8.0 or higher is required to run. And the CAR# is 251234 for future reference. This code works whenever the VI that it's operating on is in the main application context. http://ascadys.net/labview-error/labview-error-code-30.html

Share this post Link to post Share on other sites ShaunR 701 LabVIEW Archetype Members 701 3,510 posts Version:LabVIEW 2009 Since:1994 Posted September 28, 2010 (edited) If you uncheck "Include The code posted is useful for my use case and really that what matters.   Thanks for your comments! This error occurs when you try to use the Active Frame property with a Conditional Disable structure. A VI can open VI Server references only to other VIs that it could call as subVIs. http://forums.ni.com/t5/LabVIEW/passing-variant-data-in-queues-Error-code-91/td-p/1327847

Your thoughts please? This error can occur if you use a VI that is not supported in the LabVIEW Run-Time Engine. −4404 The value for palette width is invalid. altenbach Knight of NI ‎11-11-2012 02:55 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator Here's a quick illustration. Another possible cause for this error is there might be a bad network connection.

If Iload A.lvclass in AppInstance 1, that same piece of data cannot be usedin AppInstance 2 because if we close AppInstance 1, the class leaves memory, which wouldleave the data in Wenn ich aber diese Zahlen irgendwie verwenden möchte bekomme ich den Fehler : Error 91 Possible reason(s): LabVIEW: The data type of the variant is not compatible with the data type Register a new account Sign in Already have an account? Recommended Repair based on your search of "Error Code 91 Labview" Copyright © 2013-2014

Error Code 41 Amyuni | Error Code 6 Nintendo Ds | Error Code 8 Outlook Unable

A bug? Must be something wrong with your version of LV2009SP1 or mine. A bad format specifier was found in the Format String input to a Format Into String or Scan From String function. 83 Too few format specifiers. http://zone.ni.com/reference/en-XX/help/371361J-01/lverror/misc_lv_error_codes/ An overwrite error has occurred because the application is not reading data quickly enough from the buffer. 4822 A timeout occurred before the operation finished.

Text-Ring zu ersetzen. I am curious if this has anything to do with it. Thanks for the quick reponse! 0 Kudos Message 3 of 3 (1,686 Views) Reply 0 Kudos All Forum Topics Previous Topic Next Topic Privacy | Terms of Use | Other Legal Doh!

I just switched the order and now it's working. have a peek here A specified refnum was not valid. −1967345151 Invalid property code. Vielen Dank! Share this post Link to post Share on other sites Create an account or sign in to comment You need to be a member in order to leave a comment Create

A VI item in the palette data array is not supported in this version of LabVIEW. news Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced Ok, so removing the include datatype fixes the issue. Create two while loops (producer + consumer).

The paths must share a directory. The result string is exactly the same as the XML string above. Ensure that the parameters values are within the supported range for the hardware and drivers. −4406 A VI item in the palette data array is not supported in this version of have a peek at these guys Problem ist jetzt: Datentyp des Tab-Controls ist im Prinzip eine Enum-Variable (vielleicht auch ein Text-Ring, da bin ich nicht ganz sicher).

When you try to convert a blank to a type of string it throws an error. Refer to the KnowledgeBase for more information about correcting errors in LabVIEW. Themen Verfasser Antworten Views Letzter Beitrag Variant-Attributsliste Hasenfuss 2 395 27.06.2016 15:10 Letzter Beitrag: Freddy Variant Attribute initialisieren NoWay 6 1.134 27.10.2015 08:56 Letzter Beitrag: IchSelbst Variant Datentyp

or @. 2 Memory is full. 4 End of file encountered. 5 File already open. 6 Generic file I/O error.

To correct this error, install the latest version of DirectX from http://www.microsoft.com/downloads. 4810 Cannot recognize sound format. Although normal allocation might run the system out of memory, frequently an out of memory error is caused by interpreting the data incorrectly and treating something that is data as the An error occurred converting from LabVIEW type to OLE variant type. 88 Run-time menu error. 89 Another user tampered with the VI password. 90 Variant attribute not found. 91 The data As I said, this is documented in the shipping docs somewhere, and I know I've typed this up before.

Several functions may not work. Most of all those troubles may have numerous achievable brings about as well. This file cannot be saved until all dependent files have been named. 1022 Wizard Template not found. 1023 Wizard template does not have a diagram. 1024 Call Instrument aborted. 1025 Application http://ascadys.net/labview-error/labview-error-code-3.html Ich grabe mal diesen uralt Thread wieder aus..

The input string does not contain data in the expected format. This normally is a user data file. 99 Incorrect file version. You cannot add an ability multiple times. 1470 Specified folder is outside the library. Sign in here.

And you can see that I changed the Label in cluster element inside the array to "Foo" and it works just fine. Solved! The Connectivity VIs are available for free download from ni.com. Oder?

Ensure that a task is active and try again. is FALSE and a queue or notifier with that name was not found, LabVIEW returns this error. 1102 The string wired to the xml string input is empty. 1103 The XML Share this post Link to post Share on other sites John Lokanis 76 The 500 club Members 76 786 posts Location:Seattle, WA Version:LabVIEW 2015 Since:1993 Posted September 28, 2010 In Right-click the Static VI Reference function on the block diagram and select Browse for Path.

VIs in libraries are saved in the form LIBRARYNAME_VINAME. The specified file is not a valid palette file (.mnu). A buffer underflow has occurred because the application is not writing data quickly enough. −4803 The sound driver or card does not support the specified operation. event.